In This Section
Product Categories
- Communication and Call Systems 345
- Emergency Lighting 118
- Fire Alarms 1582
- 2-Wire 108
- Addressable 727
- Devices 402
- Apollo 159
- CTec 69
- Apollo Protocol Audio Visual 13
- Cast 38
- Audio Visual 24
- Detection 8
- Interfaces 6
- Cast Pro 18
- Hochiki 93
- Morley 0
- Nittan 46
- System Sensor 35
- Managed Protocol Systems 156
- Panels 169
- Devices 402
- Conventional 510
- Domestic Detectors 5
- Evacuation Alert Systems 22
- Hazardous Area 74
- Radio 85
- Temporary Alarms 7
- Test Equipment 60
- Fire Ancillaries 217
- Fire Suppression and Extinguishants 44
- Gas and Water Detection 26
- Security 41
- Signs 43
- Smoke Control & Indicating Equipment 23
Product Categories
- Communication and Call Systems 345
- Emergency Lighting 118
- Fire Alarms 1582
- 2-Wire 108
- Addressable 727
- Devices 402
- Apollo 159
- CTec 69
- Apollo Protocol Audio Visual 13
- Cast 38
- Audio Visual 24
- Detection 8
- Interfaces 6
- Cast Pro 18
- Hochiki 93
- Morley 0
- Nittan 46
- System Sensor 35
- Managed Protocol Systems 156
- Panels 169
- Devices 402
- Conventional 510
- Domestic Detectors 5
- Evacuation Alert Systems 22
- Hazardous Area 74
- Radio 85
- Temporary Alarms 7
- Test Equipment 60
- Fire Ancillaries 217
- Fire Suppression and Extinguishants 44
- Gas and Water Detection 26
- Security 41
- Signs 43
- Smoke Control & Indicating Equipment 23
Cast Mains switching input output module
Cast Mains switching input output module
SKU:
ADI-1101 / CTEC / CA731
The CAST CA731 addressable Mains Switching Input/Output (I/O) module is compatible with C-TEC?s CAST ZFP/XFP panels and other `CAST? compatible fire panels.
Features
- LPCB certified to EN54-17 & 18 and Kiwa Telefication & DBI certified to EN54-13.
- Also certified to the relevant parts of EN54 with Swedish certification body SBSC.
- A mains-switching version of our CA730 input output module.
- Capable of switching 5A @ 230 V AC or 5A 30V DC.
- Incorporates the functions of a switch monitor, zone monitor and output unit.
- Can be configured to monitor any combination of the following:-
- • Up to 20 conventional detectors and 10 MCPs.
- • Any normally open switch with an EOL resistor fitted.
- • A simple normally open or closed switch (non-fault monitored).
- Onboard short-circuit loop isolator.
- 6mA typical alarm current (1.7mA typical quiescent current) @ 22-40V DC.
- Indicators for Loop polling, input faults and relay status.
- Includes volt free changeover contacts that can be used to trigger rollershutter doors, gas shut-off valves, smoke vents, etc.
- Mountable on a C-TEC NCP-26 surface box or a standard UK 25mm double gang back box (not supplied).
