In This Section
Product Categories
- Communication and Call Systems 345
- Emergency Lighting 118
- Fire Alarms 1582
- 2-Wire 108
- Addressable 727
- Conventional 510
- Domestic Detectors 5
- Evacuation Alert Systems 22
- Hazardous Area 74
- Radio 85
- Temporary Alarms 7
- Test Equipment 60
- Fire Ancillaries 217
- Fire Suppression and Extinguishants 44
- Gas and Water Detection 26
- Security 41
- Signs 43
- Smoke Control & Indicating Equipment 23
Product Categories
- Communication and Call Systems 345
- Emergency Lighting 118
- Fire Alarms 1582
- 2-Wire 108
- Addressable 727
- Conventional 510
- Domestic Detectors 5
- Evacuation Alert Systems 22
- Hazardous Area 74
- Radio 85
- Temporary Alarms 7
- Test Equipment 60
- Fire Ancillaries 217
- Fire Suppression and Extinguishants 44
- Gas and Water Detection 26
- Security 41
- Signs 43
- Smoke Control & Indicating Equipment 23
XFP Networkable Repeater 32z (all Protocols) Code / Keyswitch Entry
XFP Networkable Repeater 32z (all Protocols) Code / Keyswitch Entry
SKU:
AP-4032 / C-Tec / XFP510-32
Can be used to repeat the functions of an XFP Main panel at remote parts of a site (e.g. all potential fire service entrances).
Features
- Offers all of the functions and controls of an XFP Main panel (access levels 1, 2 and 3).
- Includes an on-board fault relay.
- Requires its own dedicated Mains power and battery back-up supply.
- A maximum of eight XFP Repeaters can be connected to one non-networked XFP Main panel.
- Communication between the XFP Main panel and Repeater requires an AFP711 network driver card (fitted as standard in all XFP510-32s, available as an optional extra on Main XFP 32 Zone panels).
- Repeater network wired in 1.5 mm2 two-core screened fire resistant cable. Network length must not exceed 500 metres.
Downloads
| Protocol/compatibility | Compatible with C-TEC’s XFP CAST, Apollo XP95/Discovery and Hochiki ESP main panels. |
|---|---|
| Mains supply | 230V 50/60Hz. |
| Mains rated current | 680mA maximum. |
| Internal power supply | 27Vdc nominal. |
| Total output current limited to | 3A @ 230Vac (Imax.A 250mA; Imin. 70mA). |
| Quiescent current | TBC. |
| Max battery size and type | 2 x 12V 7Ah VRLA connected in series. |
| Auxiliary relays | Fault (Failsafe; Capable of switching 1A @ 30V DC; Must not be used for switching Mains voltages). |
| PC connection | None. |
| Indicators | 2 line x 40 character backlit display; 32 Zonal LEDs, General Fire; Energised; Pre-Alarm; Remote Output Activated; Remote Output Disabled; Accessed; Disablement; Test; Silenced; General Fault; System Fault. |
| Expansion connections | On board AFP711 network driver card facilitates the connection of additional XFP Repeaters. |
| Product dimensions (mm) | 410 W x 250 H x 80 D mm (base); 439 W x 274 H x 7 D mm (lid). |
| Construction & finish | Metal. |
| IP Rating | TBC. |
| Weight | 4.5kg (no batteries). |
| Operating conditions/temperature | -5ºC to +40ºC. Max relative humidity: 95%. |
| Network specification | Max. no. of Repeaters per Main XFP: 8 (any mix); Max. total length of Repeater network: 500m; Cabling requirements: 1.5mm2 two core screened fire resistant. |